Mga Parameter ng Produkto

· YJLHV 8030 series na aluminum alloy cable

-YJLHV ay isang mataas na flexibility na uri ng aluminyo haluang metal 90 ℃ crosslinked polyethylene insulated single core o multi-core aluminum alloy cable.
-WDZA-YJLHV type flame retardant grade A aluminum alloy cable ay maaari ding gawin ayon sa pangangailangan ng customer.

· Pamantayan ng produkto

1.GB/T12706-2008 rated boltahe lkV(Um=1.2KV)sa 35KV(Um=40.5KV)extruded insulatedpower cable at mga accessories
2.GB/T19666-2005 flame retardant at fire-resistant wire at cable pangkalahatang panuntunan
3.Q/320282 DDF029-2012 cable na may 8000 series na aluminum alloy conductor
4.GB/T 31840-2015rated na boltahe 1KV(Um=1.2KV)hanggang 35KV(Um=40.5KV)extrudedinsulated aluminum alloy core power cable

· Mga tampok ng produkto

1. Ang 8030 series na aluminum alloy conductor na binuo ng ating sarili ay may mga katangian ng mataas na conductivity, magandang paglaban sa wax degeneration, mataas na flexibility, mataas na extension, mababang rebound at stable na koneksyon, at ang pagganap nito ay lumampas sa mga kinakailangan sa pagganap ng ASTMB800-05 standard.
2. Ang mataas na lakas na 5000 series na aluminyo haluang metal ay malakas at matigas, na may mahusay na baluktot at mahusay na pagganap ng kalasag;
3. Ang cable ay hindi naglalaman ng mabibigat na elemento ng metal, berdeng proteksyon sa kapaligiran, ang flameretardant na pagganap ay umabot sa halogen-free low smoke flame retardant class A.
4. Ang cable ay maaaring matatagpuan sa loob ng bahay, direktang nakabaon sa dingding at sa tuyong kapaligiran ng tunel, magaan ang timbang, nakakatipid sa gastos ng pag-install ng tulay, atbp., at may bilang ng mga mode ng pipeline
5.Itakda ang parehong pagganap.

Talahanayan ng mga teknikal na parameter

·Talahanayan 1, YJLHV YJLHY-1 ~3kv aluminum alloy cable talahanayan ng pisikal na parameter

Nominal
seksyon
(mm²)
Tinatayang panlabas diameter ng cable (mm) Tinatayang bigat ng cable (kg/km)
2
Mga core
3
Mga core
4
Mga core
3 1
Mga core
5
Mga core
4 1
Mga core
3 2
Mga core
2
Mga core
3
Mga core
4
Mga core
3 1
Mga core
5
Mga core
4 1
Mga core
3 2
Mga core
10 17.6 20.5 21.9 21.3 23.4 23.0 22.4 132 174 220 203.1 272 253 237
16 19.7 22.7 24.3 23.7 26.1 25.8 25.2 180 242 307 285 359 359 337
25 21.7 26.1 28.2 27.3 30.4 29.8 28.9 260 355 454 418 529 529 489
35 24.9 28.3 30.3 29.1 33.1 32.0 30.6 331 457 587 517 661 661 595
50 26.9 31.5 33.1 32.8 36.1 35.0 33.7 445 621 804 717 916 916 826
70 29.39 34.3 37.5 35.5 40.9 39.5 37.7 582 819 1063 944 1218 1218 1094
95 33.5 37.3 40.8 39.0 44.7 43.4 41.6 741 1051 1369 1228 1582 1582 1430
120 35.2 41.0 44.9 43.2 49.3 48.1 46.4 917 1309 1709 1548 1984 1984 1817
150 38.6 44.6 49.0 46.2 53.9 51.8 49.2 1117 1601 2094 1837 2382 2382 2118
185 42.0 49.6 54.6 51.3 64.3 57.6 54.5 1367 1967 2577 2276 2946 2946 2642
240 46.6 55.0 64.8 56.8 71.1 68.2 64.6 1724 2491 3422 2880 3893 3893 3493
300 516 63.9 70.1 66.0 77.0 73.9 70.1 2099 3195 4170 3682 4750 4750 4264
400 56.0 71.2 78.3 73.6 86.2 82.6 78.2 2892 4152 5434 4755 6131 6131 5454
500 67.0 78.8 86.8 81.5 95.6 91.6 86.6 3558 5128 6723 5899 7589 7589 6768
630 74.0 87.6 87.6 90.2 106.7 101.7 95.7 4408 6375 8370 7322 9415 9415 8370

·Talahanayan 2. YJLHV YJLHY-1 ~3kV aluminum alloy cable current carrying meter

Nominal
seksyon
Tinatayang
panlabas na diameter
ng konduktor
Nominal
pagkakabukod
kapal
lkv
1.8/3 nominal
pagkakabukod
kapal
DC
paglaban
sa 20 ℃
Kapasidad ng pagdadala
2 Mga Core 3~5 Mga Core
mm2 mm mm mm ≤2/km A A A A
10 3.80 0.7 2.0 3.08 67 83 57 70
16 4.80 0.7 2.0 191 86 106 75 91
25 6.00 0.9 2.0 1.21 114 138 100 117
35 6.60 0.9 2.0 0.868 137 165 120 138
50 7.70 1.0 2.0 0.641 171 197 149 170
70 9.22 1.1 2.0 0.443 217 239 189 207
95 10.90 1.1 2.0 0.320 268 292 234 250
120 12.30 1.2 2.0 0.253 314 334 274 281
150 13.50 1.4 2.0 0.206 360 371 308 318
185 15.30 1.6 2.0 0.164 417 419 360 361
240 17.40 1.7 2.0 0.125 496 499 428 419
300 19.50 1.8 2.0 0.100 582 581 496 472
400 22.00 2.0 2.0 0.0778 673 663 582 541
500 26.00 2.2 2.0 0.0605 781 764 702 626
630 30.20 2.4 2.0 0.0469 930 901 833 711
Temperatura sa paligid/Nakabaon na lalim 0.7m 30 ℃ 20 ℃ 30 ℃ 20 ℃
Pinakamataas na temperatura ng pagpapatakbo ng konduktor 90℃

Wuxi Sanxin Cable Co., Ltd.

Tungkol sa Amin

Ang kumpanya ay dalubhasa sa higit sa 1,000 uri ng produkto at higit sa 10,000 mga detalye, kabilang ang mga Overhead Conductors, High and Low Voltage Cross-linked Cables, Flame Retardant at Fire Resistant Cables, Control Cable, Specialty Cable, atbp. ang aming mga produkto ng cable ay sumasailalim sa mahigpit na pagsubok sa pagganap at sertipikasyon sa kaligtasan, at malawak na ginagamit sa mga patlang ng industriya at konstruksyon. nakatutok sa patuloy na pag-unlad ng aming mga cable na may mataas at mababang boltahe, na tinitiyak na naaayon ang mga ito sa umuusbong na teknolohiya at mga pamantayan ng kalidad. Ang mga advanced na kagamitan, mahigpit na proseso ng produksyon at pinong craftsmanship ay nagpapahusay sa kahusayan sa produksyon at kalidad ng produkto ng aming mataas at mababang boltahe na mga cable. Gamit ang matatag na kakayahan sa produksyon, mabilis kaming tumugon sa mga pangangailangan ng merkado para sa iba't ibang antas ng mataas at mababang boltahe na mga cable.